1 × $318.00
-
1 × $30,911.00
-
1 × $2,338.00
-
1 × $5,455.00
-
1 × $997.00
-
1 × $1,253.00
-
1 × $1,471.00
-
1 × $855.00
-
1 × $2,468.00
-
1 × $516.00
-
1 × $3,652.00
-
3 × $147.00
-
Keysight N5171B EXG X-Series Signal Generator: Unleash Precision and Versatility from 9 kHz to 1 GHz1 × $7,328.00
-
1 × $555.00
-
1 × $1,512.00
-
1 × $2,664.00
-
1 × $1,332.00
-
2 × $270.00
-
1 × $754.00
-
1 × $5,077.00
-
1 × $1,253.00
-
1 × $339.00
-
1 × $1,659.00
-
1 × $1,977.00
-
1 × $871.00
-
1 × $6,104.00
-
1 × $4,247.00
-
1 × $2,271.00
-
1 × $333.00
-
1 × $971.00
-
1 × $5,455.00
-
1 × $912.00
-
2 × $393.00
-
1 × $147.00
-
1 × $353.00
-
1 × $238.00
-
1 × $947.00
-
1 × $322.00
-
1 × $3,994.00
-
1 × $2,271.00
-
1 × $167.00
-
1 × $12,987.00
-
1 × $107.00
-
1 × $1,798.00
-
1 × $222.00
-
1 × $649.00
-
1 × $4,139.00
-
1 × $9,803.00
Featuring the latest in pulse width modulation technology, the Model 4120 employs a high frequency power source and voltage/current feedback circuits to product a stable, high voltage output with low ripple. A front panel feature, unique to the Model 4120 allows the operator to test Metal Oxide Arresters quickly and accurately. Another feature that is as unique as it is useful is a high-voltage dc micro-ammeter use to test leakage currents on the high-voltage side of the insulation testing circuit.
Features
- Pulse width Modulation (PWM) technology
- Stable, high-precision voltage adjustment
- Comprehensive nanosecond threshold protection
- Unique Metal oxide test function
- Adjustable overvoltage protection feature
- Current limiting resistor for capacitive load testing
- Shielded HV micro-ammeter accessory
- Shorting rod for grounding output after testing
>
Specifications
- Rated voltage: 120 kVDC
- Rated current: 5 mADC
- Rated power: 360 W
- Weight: 22 lbs.
- Power supply: 120 VAC ±10%, 60 Hz
- Dimensions (Control Unit): 16.25 x 15.5 x 7.5
- Output voltage accuracy: ±(1.0% reading, ±2 digits)
- Output current accuracy: ±(1.0% reading, ±2 digits)
- Ripple factor: ?0.5%
- Working mode: Intermittent use, 30 minutes under rated load
- Overload Voltage: The no-load voltage can exceed the rated voltage 10% for 10 minutes.
- Overload Current: The maximum charge current is 1.25 times of the rated current.
- Operating environment: Temperature 14°F to 104°F
- Humidity: To ?85%RH for temperatures under 77°F, non-condensing
- Altitude: Under 4,900
>
Each Unit Includes
Manual, power cord, and NIST Traceable Certificate of Calibration.