1 × $1,055.00
-
1 × $325.00
-
1 × $1,449.00
-
1 × $905.00
-
1 × $1,793.00
-
1 × $3,904.00
-
1 × $9,133.00
-
1 × $1,547.00
-
1 × $14,482.00
-
1 × $598.00
-
1 × $1,330.00
-
1 × $1,177.00
-
1 × $2,106.00
-
1 × $1,852.00
-
1 × $1,508.00
-
1 × $1,449.00
-
1 × $1,055.00
-
1 × $1,055.00
-
1 × $1,177.00
-
1 × $1,885.00
-
1 × $947.00
-
1 × $11,170.00
-
1 × $12,771.00
-
1 × $1,737.00
-
1 × $156.00
-
1 × $1,429.00
-
1 × $526.00
-
1 × $1,350.00
-
1 × $5,714.00
-
1 × $1,337.00
-
2 × $1,713.00
-
1 × $2,212.00
-
1 × $1,572.00
-
1 × $956.00
-
1 × $1,155.00
-
1 × $653.00
-
1 × $338.00
-
1 × $9,493.00
-
1 × $1,337.00
-
1 × $1,337.00
-
1 × $2,240.00
-
1 × $930.00
-
2 × $1,337.00
-
1 × $671.00
-
2 × $1,063.00
-
1 × $1,259.00
-
1 × $1,713.00
-
1 × $1,449.00
-
1 × $519.00
-
1 × $272.00
-
1 × $270.00
-
1 × $343.00
-
1 × $322.00
-
1 × $2,472.00
-
1 × $912.00
-
1 × $28,963.00
-
1 × $394.00
-
1 × $762.00
-
1 × $130.00
-
1 × $322.00
-
1 × $2,170.00
-
1 × $1,009.00
Featuring the latest in pulse width modulation technology, the Model 4120 employs a high frequency power source and voltage/current feedback circuits to product a stable, high voltage output with low ripple. A front panel feature, unique to the Model 4120 allows the operator to test Metal Oxide Arresters quickly and accurately. Another feature that is as unique as it is useful is a high-voltage dc micro-ammeter use to test leakage currents on the high-voltage side of the insulation testing circuit.
Features
- Pulse width Modulation (PWM) technology
- Stable, high-precision voltage adjustment
- Comprehensive nanosecond threshold protection
- Unique Metal oxide test function
- Adjustable overvoltage protection feature
- Current limiting resistor for capacitive load testing
- Shielded HV micro-ammeter accessory
- Shorting rod for grounding output after testing
>
Specifications
- Rated voltage: 120 kVDC
- Rated current: 5 mADC
- Rated power: 360 W
- Weight: 22 lbs.
- Power supply: 120 VAC ±10%, 60 Hz
- Dimensions (Control Unit): 16.25 x 15.5 x 7.5
- Output voltage accuracy: ±(1.0% reading, ±2 digits)
- Output current accuracy: ±(1.0% reading, ±2 digits)
- Ripple factor: ?0.5%
- Working mode: Intermittent use, 30 minutes under rated load
- Overload Voltage: The no-load voltage can exceed the rated voltage 10% for 10 minutes.
- Overload Current: The maximum charge current is 1.25 times of the rated current.
- Operating environment: Temperature 14°F to 104°F
- Humidity: To ?85%RH for temperatures under 77°F, non-condensing
- Altitude: Under 4,900
>
Each Unit Includes
Manual, power cord, and NIST Traceable Certificate of Calibration.











Reviews