1 × $1,453.00
-
1 × $4,633.00
-
2 × $322.00
-
1 × $4,193.00
-
1 × $1,106.00
-
1 × $322.00
-
1 × $121.00
-
1 × $6,853.00
-
1 × $653.00
-
1 × $598.00
-
1 × $1,055.00
-
1 × $1,634.00
-
1 × $1,449.00
-
1 × $628.00
-
1 × $5,305.00
-
1 × $879.00
-
1 × $2,514.00
-
1 × $674.00
-
1 × $147.00
-
3 × $381.00
-
1 × $2,451.00
-
1 × $905.00
-
1 × $498.00
-
1 × $130.00
-
1 × $114.00
-
1 × $5,707.00
-
1 × $2,765.00
-
1 × $2,011.00
-
1 × $762.00
-
2 × $4,306.00
-
1 × $2,250.00
-
1 × $334.00
-
1 × $1,306.00
-
1 × $1,658.00
-
1 × $519.00
-
1 × $25,082.00
-
1 × $1,634.00
-
1 × $653.00
-
1 × $1,717.00
-
1 × $1,391.00
-
1 × $407.00
-
1 × $1,826.00
-
1 × $846.00
-
1 × $1,542.00
-
1 × $8,958.00
-
1 × $113.00
-
1 × $2,019.00
-
1 × $148.00
-
1 × $163.00
-
1 × $8,766.00
-
1 × $1,737.00
-
1 × $280.00
-
1 × $145.00
-
1 × $348.00
-
1 × $728.00
-
1 × $5,663.00
-
1 × $370.00
-
1 × $1,608.00
-
1 × $603.00
-
1 × $1,353.00
-
1 × $5,195.00
-
1 × $1,889.00
-
1 × $1,063.00
-
1 × $489.00
-
1 × $4,206.00
-
1 × $2,170.00
-
1 × $905.00
-
1 × $1,123.00
-
1 × $574.00
-
1 × $393.00
-
1 × $3,050.00
-
1 × $12,401.00
-
1 × $6,744.00
-
1 × $971.00
- Simultaneously measure demand and harmonic waveforms that share the same voltage line over 4-circuits
- Data can be saved onto a PC card
- High-speed and continuous processing to measure individual waveforms
- Measurement line & number of circuits Single-phase 2-wires (4 circuits), Single-phase 3-wires (2 circuits), Three-phases 3-wires (2 or 1 circuit), and Three-phases 4-wires (1 circuit)
- Note: 50 or 60 Hz, and that share the same voltage line
- Measurement items Voltage, Current, Active/ reactive/ apparent power, Active/ reactive power integration, Power factor, Frequency, Harmonic waveform value
- Voltage ranges 150.00 V to 600.00 V AC, 3 ranges
- Current ranges 500.00 mA to 5.0000 kA AC (depends on current sensor in use)
- Power ranges 75.000 W to 900.00 kW (depends on combination of voltage, current range, and measurement line)
- Basic accuracy AC Voltage: ±0.2 % rdg. ±0.1 % f.s.
- AC Current: ±0.2 % rdg. ±0.1 % f.s. current sensor accuracy
- Active power: ±0.2 % rdg. ±0.1 % f.s. current sensor accuracy (at power factor = 1)
- CLAMP ON SENSOR 9661: ±0.3 % rdg. ±0.01 % f.s. (different from each model)
- Measurement method Digital sampling, PLL synchronization or 50/60 Hz fixed clock
- Basic accuracy Active power: ±0.2% rdg. ±0.1% f.s. clamp-on sensor accuracy (at 45 to 66 Hz)
- Display refresh rate 2 times /sec (except when using a PC card while accessing the internal memory, or when performing RS-232C communications)
- Data save interval Standard interval: 1 sec to 30 sec, 1 minute to 60 minutes, 13 selects
- Fast interval: A single waveform, or 0.1, 0.2, or 0.5 sec (at instant value only)
- Frequency characterristics Fundamental waveforms up to the 50th order ±3% f.s. measurement accuracy (of a 45 to 66 Hz fundamental waveform)
- Other functions Error connect check, language selection, display hold, setting backup, power shut off management, key lock, [3169-21 only] D/A output 4 channels, ±5 V DC f.s.)
- Power supply 100 to 240 V AC, 50/60 Hz, 30 VA max.
- Dimensions, mass 210 mm (8.27 in) W × 160 mm (6.30 in) H × 60 mm (2.36 in) D, 1.2 kg (42.3 oz)
>
Each Unit Includes
- VOLTAGE CORD L9438-53 (Black/ Red/ Yellow/ Blue)
- Power cord
- Instruction Manual
- Quick Start Manual
- CD-R (RS-232C interface operating manual)
- Input cord label