-
1 × $272.00
-
1 × $272.00
-
1 × $1,458.00
-
1 × $21,508.00
-
2 × $9,744.00
-
1 × $201.00
-
1 × $9,403.00
-
1 × $477.00
-
1 × $674.00
-
1 × $7,951.00
-
1 × $382.00
-
1 × $3,368.00
-
1 × $1,337.00
-
1 × $1,453.00
-
1 × $1,680.00
-
1 × $298.00
-
1 × $360.00
-
1 × $519.00
-
1 × $951.00
-
1 × $416.00
-
2 × $1,449.00
-
2 × $515.00
-
1 × $1,449.00
-
2 × $1,453.00
-
1 × $5,641.00
-
1 × $184.00
-
1 × $959.00
-
1 × $922.00
-
1 × $5,195.00
-
1 × $603.00
-
1 × $6,744.00
-
1 × $2,111.00
-
2 × $5,663.00
-
1 × $12,987.00
-
1 × $5,195.00
-
1 × $1,449.00
-
2 × $4,206.00
-
2 × $1,055.00
-
1 × $1,449.00
-
1 × $101.00
-
1 × $1,893.00
-
1 × $5,781.00
-
1 × $3,004.00
-
1 × $3,016.00
-
1 × $1,512.00
-
1 × $1,680.00
-
1 × $658.00
-
1 × $759.00
-
1 × $108.00
-
1 × $1,512.00
-
1 × $2,791.00
-
1 × $1,337.00
-
1 × $4,525.00
-
2 × $1,449.00
-
1 × $1,357.00
-
1 × $1,449.00
-
1 × $360.00
-
1 × $1,337.00
-
1 × $1,860.00
-
1 × $1,709.00
-
1 × $272.00
-
1 × $2,965.00
-
1 × $846.00
-
1 × $888.00
-
1 × $959.00
-
1 × $1,337.00
-
1 × $13,897.00
-
1 × $272.00
-
1 × $2,626.00
-
1 × $7,624.00
-
1 × $959.00
-
1 × $959.00
-
1 × $1,705.00
-
1 × $119.00
-
1 × $553.00
-
1 × $6,862.00
-
1 × $3,016.00
-
1 × $980.00
-
1 × $1,307.00
-
1 × $783.00
-
1 × $1,449.00
-
1 × $2,175.00
-
1 × $1,680.00
-
1 × $6,753.00
-
1 × $135.00
-
1 × $959.00
-
1 × $332.00
- Built specifically for the Test described in IEC 60950, Annex N, Table N.1, Line 1 and IEC 62368-1, Annex D, Table D.1, Line 1.
- Charges the bulk capacitor to the required 2.5kV or 7kV (Australian Deviation), using the front panel knob or optionally via USB, see TMM-PF option.
- Discharge of the 6838V output pulse is controlled by the front panel TEST button or optionally via USB, see TMM-PF option.
- Meter reads the bulk capacitor voltage per the requirements of IEC 60950.
- Polarity can be changed by the front panel POLARITY button or optionally via USB, see TMM-PF option.
- Cables and NIST Calibration Certificate Included, A2LA Calibration optional.
- One year warranty and unlimited telephone support.
>
MegaPulse 10700-7PF, bulk cap voltages of 2000-7000V, 10x700uSec Voltage Waveform, 40 ohm 1 chnl. Designed specifically for testing to IEC 60950 and IEC 62368-1, including the Australian Deviation. Includes self-regulating high-voltage power supply for more stable voltage control.
Optional TestMinder PF computer control and 1000:1 Oscilloscope output (reference only). Option IER equips the tester with a switch compliant with IEC 60065, Fig. 7B.
In accordance with the requirements of IEC 60950, IEC 62368-1 and ITU-T Standards, the meter reads the bulk capacitor voltage.
Calibrated at bulk cap voltages of 1000-7000V to reflect the test points of IEC 60950, IEC 62368-1 and the Australian Deviation. ISO 17025 calibration available.











Reviews
There are no reviews yet.