1 × $1,164.00
-
1 × $109.00
-
1 × $553.00
-
1 × $13,897.00
-
1 × $23,996.00
-
1 × $3,050.00
-
1 × $12,485.00
-
1 × $1,348.00
-
1 × $1,634.00
-
1 × $997.00
-
1 × $475.00
-
1 × $1,449.00
-
1 × $322.00
-
1 × $1,549.00
-
1 × $360.00
-
1 × $1,549.00
-
1 × $536.00
-
1 × $1,977.00
-
1 × $2,066.00
-
1 × $1,818.00
-
1 × $527.00
-
1 × $1,818.00
-
1 × $1,231.00
-
1 × $1,136.00
-
1 × $385.00
-
1 × $6,916.00
-
1 × $269.00
-
1 × $1,818.00
-
1 × $979.00
-
1 × $1,818.00
-
1 × $1,449.00
-
1 × $10,390.00
-
1 × $503.00
-
1 × $1,516.00
-
1 × $3,202.00
-
1 × $14,761.00
-
1 × $109.00
-
1 × $473.00
-
1 × $1,449.00
-
1 × $280.00
-
1 × $256.00
-
1 × $1,357.00
-
1 × $1,901.00
-
1 × $2,639.00
-
1 × $1,960.00
-
2 × $1,457.00
-
1 × $2,144.00
-
1 × $236.00
-
1 × $1,026.00
-
1 × $5,253.00
-
1 × $838.00
-
1 × $170.00
-
1 × $997.00
-
1 × $1,559.00
-
1 × $322.00
-
1 × $867.00
-
1 × $2,250.00
-
1 × $1,449.00
-
1 × $1,572.00
-
1 × $1,516.00
-
1 × $1,818.00
-
1 × $186.00
-
1 × $2,161.00
-
1 × $1,273.00
-
1 × $1,985.00
-
1 × $595.00
-
1 × $214.00
-
1 × $310.00
-
1 × $1,512.00
-
1 × $3,734.00
-
1 × $243.00
-
1 × $446.00
-
1 × $2,179.00
-
1 × $1,901.00
-
1 × $1,231.00
-
1 × $959.00
-
1 × $544.00
THE MRU-200-GPS OFFERS A VARIETY OF MEASUREMENT METHODS FOR GROUND RESISTANCE AND RESISTIVIY.
The MRU-200-GPS is the only meter which can perform all ground resistance measurement methods, 2-pole, 3-pole, 4-pole, and impulse earth impedance methods.
- Ground resistance using auxiliary electrodes, or with electrodes and clamp for measurements in the presence of multiple ground paths
- Ground resistance using double clamps when it is not possible to use auxiliary electrodes
- Impulse ground resistance without disconnecting measured grounding
- Soil resistivity using Wenner method
- Leakage current using current clamp or flexible Rogowsky probe
- Measurement of continuity of equipotential bonding and protective conductors (meets IEC 60364-6-61:2000 section 6.12.2) with auto-zero function and 200 mA current
- Ground resistance measurement, with 2-pole, 3-pole, or 4-pole methods
- Leakage current measurement
- Selective measurement with clamp excludes influence from parallel ground points
- No opening of rusted conductors needed
- Impulse ground resistance measurement at 4/10 µs, 8/20 µs, or 10/350 µs
- Two clamps resistance measurement method without auxiliary test probes
- GPS coordinates of measurement location are stored with test results
- Resistance measurement of auxiliary electrodes
- Measurement of interference voltage and interference frequency
- Measurement in the presence of interference voltages at 162/3 Hz, 50 Hz, 60 Hz, and 400 Hz
- Automatic or manual selection of frequency of measuring signal
- Selection of maximum measuring voltage (25 V and 50 V)
- Distance between the electrodes noted in meters (m) and feet (ft)
- Memory storage for 990 measurements
- Calibration information of test clamp(s)
- Real-time clock
- USB interface for PC connection
- Internal battery with indication of state of charge
- Backlit LCD graphic display
- Double insulated meets IEC 61010-1 and IEC 61557 standards CAT IV 300 V