1 × $360.00
-
1 × $381.00
-
1 × $215.00
-
2 × $257.00
-
1 × $1,977.00
-
1 × $448.00
-
1 × $997.00
-
1 × $3,268.00
-
1 × $652.00
-
2 × $109.00
-
1 × $4,206.00
-
1 × $1,063.00
-
1 × $959.00
-
1 × $959.00
-
1 × $3,418.00
-
1 × $214.00
-
1 × $3,368.00
-
1 × $3,734.00
-
1 × $360.00
-
1 × $393.00
-
1 × $20,683.00
-
1 × $205.00
-
1 × $1,429.00
-
1 × $1,634.00
-
1 × $1,449.00
-
1 × $1,851.00
-
1 × $385.00
-
1 × $1,449.00
-
1 × $1,365.00
-
1 × $1,357.00
-
1 × $114.00
-
1 × $5,488.00
-
1 × $2,790.00
-
1 × $754.00
-
1 × $283.00
-
1 × $1,337.00
-
1 × $855.00
-
1 × $113.00
-
1 × $15,459.00
-
1 × $6,104.00
-
1 × $595.00
-
1 × $498.00
-
1 × $2,170.00
-
1 × $1,893.00
-
1 × $5,446.00
-
2 × $3,652.00
-
1 × $1,449.00
-
1 × $1,680.00
-
1 × $9,133.00
-
1 × $6,744.00
-
1 × $959.00
-
1 × $1,449.00
-
1 × $867.00
-
1 × $2,179.00
-
1 × $1,512.00
-
1 × $27,148.00
-
1 × $322.00
-
1 × $2,890.00
-
1 × $13,524.00
-
1 × $796.00
THE MRU-200-GPS OFFERS A VARIETY OF MEASUREMENT METHODS FOR GROUND RESISTANCE AND RESISTIVIY.
The MRU-200-GPS is the only meter which can perform all ground resistance measurement methods, 2-pole, 3-pole, 4-pole, and impulse earth impedance methods.
- Ground resistance using auxiliary electrodes, or with electrodes and clamp for measurements in the presence of multiple ground paths
- Ground resistance using double clamps when it is not possible to use auxiliary electrodes
- Impulse ground resistance without disconnecting measured grounding
- Soil resistivity using Wenner method
- Leakage current using current clamp or flexible Rogowsky probe
- Measurement of continuity of equipotential bonding and protective conductors (meets IEC 60364-6-61:2000 section 6.12.2) with auto-zero function and 200 mA current
- Ground resistance measurement, with 2-pole, 3-pole, or 4-pole methods
- Leakage current measurement
- Selective measurement with clamp excludes influence from parallel ground points
- No opening of rusted conductors needed
- Impulse ground resistance measurement at 4/10 µs, 8/20 µs, or 10/350 µs
- Two clamps resistance measurement method without auxiliary test probes
- GPS coordinates of measurement location are stored with test results
- Resistance measurement of auxiliary electrodes
- Measurement of interference voltage and interference frequency
- Measurement in the presence of interference voltages at 162/3 Hz, 50 Hz, 60 Hz, and 400 Hz
- Automatic or manual selection of frequency of measuring signal
- Selection of maximum measuring voltage (25 V and 50 V)
- Distance between the electrodes noted in meters (m) and feet (ft)
- Memory storage for 990 measurements
- Calibration information of test clamp(s)
- Real-time clock
- USB interface for PC connection
- Internal battery with indication of state of charge
- Backlit LCD graphic display
- Double insulated meets IEC 61010-1 and IEC 61557 standards CAT IV 300 V