1 × $287.00
-
1 × $5,663.00
-
1 × $220.00
-
1 × $229.00
-
1 × $1,449.00
-
1 × $477.00
-
1 × $805.00
-
2 × $6,242.00
-
1 × $1,929.00
-
1 × $993.00
-
1 × $2,882.00
-
1 × $427.00
-
1 × $1,810.00
-
1 × $19,742.00
-
1 × $2,715.00
-
1 × $930.00
-
1 × $7,022.00
-
1 × $200.00
-
1 × $1,273.00
-
1 × $188.00
-
1 × $483.00
-
1 × $512.00
-
2 × $2,698.00
-
1 × $8,044.00
-
1 × $532.00
-
2 × $15,521.00
-
1 × $342.00
-
2 × $1,533.00
-
1 × $180.00
-
1 × $930.00
-
1 × $1,407.00
-
2 × $3,033.00
-
1 × $905.00
-
1 × $2,292.00
-
1 × $105.00
-
1 × $1,194.00
-
1 × $128.00
-
1 × $108.00
-
1 × $896.00
-
1 × $2,965.00
-
2 × $1,961.00
-
1 × $232.00
-
1 × $1,998.00
-
1 × $164.00
-
1 × $5,707.00
-
2 × $190.00
-
1 × $109.00
-
1 × $4,421.00
-
1 × $12,569.00
-
1 × $116.00
-
1 × $1,985.00
-
1 × $201.00
-
1 × $5,337.00
-
1 × $33,119.00
-
1 × $20,683.00
-
1 × $506.00
-
1 × $113.00
-
1 × $3,650.00
-
1 × $105.00
-
1 × $5,337.00
-
1 × $107.00
-
1 × $3,284.00
-
1 × $2,111.00
-
1 × $310.00
-
1 × $3,130.00
-
1 × $2,279.00
-
1 × $4,206.00
-
1 × $489.00
-
2 × $156.00
-
1 × $5,136.00
-
1 × $3,267.00
-
1 × $595.00
-
1 × $3,159.00
-
1 × $172.00
-
1 × $1,063.00
-
1 × $594.00
-
1 × $3,159.00
-
1 × $20,228.00
-
1 × $2,085.00
-
1 × $3,572.00
-
1 × $4,211.00
-
1 × $1,361.00
-
1 × $1,245.00
-
1 × $120.00
-
1 × $4,919.00
-
1 × $2,533.00
-
1 × $116.00
-
1 × $3,418.00
-
1 × $201.00
-
1 × $1,974.00
-
1 × $154.00
-
1 × $15,975.00
-
1 × $2,882.00
-
1 × $2,069.00
- Requires optional probe, sold separately
- Measurement Capability Channel 1: 4-wire RTD, Thermistor, Thermocouple, Resistance, Voltage
- Measurement Capability Channel 2: 4-wire RTD, Thermistor, Resistance
- Accuracy to ±0.002 °C with thermistors and ± 0.015°C with PRTs
- Temperature range: –200°C to 2315°C
- Simultaneously measures two channels
- Reads PRTs, thermocouples, and thermistors
- “Plug-and-play” calibration coefficients with SMART LEMO connector
- Trends data graphically
- Documents readings and statistics
- Logs up to 15,000 data points
- Graphing Yes
- Documenting 25 readings
- Auto Logging 15,000 readings
- Statistics Average, Stdev, Max, Min
- Internal real-time clock
- Units °C, °F, Ω, mV
- Environmental conditions for all
- specifications 13°C to 33°C and 0 to 90% RH
- Storage Temperature -20°C to 70°C
- RTD Resistance Accuracy 0.004% 0.002 Ω percent of reading floor
- Thermistor Resistance Accuracy 0.01% 0.5 Ω percent of reading floor
- Thermocouple Voltage Accuracy 0.005% of reading 5µV floor
- TC Reference Junction Compensation Accuracy 0.35°C
- TC Measurement Capability Types J, K, T, E, R, S, B, L, U, C, M and N
- Weight (kg) 0.65
- Dimensions WxHxL (mm) 96x200x47
- Computer Communications RS-232 – SCPI protocol
- Baud Rate 2400, 9600
- Power Requirements 3 AA Batteries
- DC universal power supply
- Minimum Battery Life 20 hours
>
Each Unit Includes
- NIST traceable Certificate of calibration
- Users Guide
- CD-ROM (contains Technical Manual)
- RS-232 serial cable
- Software for computer interface
- Power Supply