-
1 × $7,951.00
-
1 × $6,477.00
-
2 × $1,337.00
-
1 × $1,713.00
-
1 × $1,055.00
-
1 × $1,680.00
-
1 × $959.00
-
1 × $1,391.00
-
1 × $7,842.00
-
1 × $951.00
-
1 × $9,635.00
-
1 × $1,139.00
-
1 × $1,290.00
-
1 × $1,337.00
-
1 × $21,300.00
-
1 × $1,655.00
-
1 × $1,210.00
-
1 × $2,069.00
-
1 × $1,391.00
-
1 × $5,195.00
-
1 × $3,761.00
-
1 × $1,893.00
-
1 × $29,548.00
-
1 × $1,063.00
-
1 × $5,663.00
-
1 × $959.00
-
1 × $515.00
-
1 × $968.00
-
EA Elektro-Automatik EA-PS 11000-10 2U DC Power Supply, Autoranging, Single Output, 1000 VDC, 10 ADC1 × $4,351.00
-
1 × $2,597.00
-
1 × $1,453.00
-
1 × $22,261.00
-
2 × $1,713.00
-
1 × $5,446.00
-
1 × $2,271.00
-
1 × $759.00
-
2 × $1,337.00
-
1 × $214.00
-
1 × $6,175.00
-
1 × $1,365.00
-
1 × $5,077.00
-
1 × $1,337.00
-
1 × $5,002.00
-
1 × $11,170.00
-
1 × $2,078.00
-
1 × $1,680.00
-
1 × $3,368.00
-
1 × $515.00
-
1 × $4,206.00
-
1 × $980.00
- High precision leakage current, duration and ground continuity settings.
- Allows no load setup of leakage current and test dwell times.
- Once entered, ground continuity setting, leakage current and test dwell times can be referenced on the front panel display when unit is not testing.
- Leakage currents can be set from 1-20 mA AC or 1-5 mA DC in 0.1mA increments.
- Dwell times can be set from 1-60 seconds in 1 second increments.
- Two tests with one setup. Conducts UL/CSA Ground continuity and Hipot tests with one setup, so no additional equipment is needed.
- Small and light. 9.25 wide x 4.75 high x 10 deep. 11 lbs. But rugged enough to test manufactured housing.
- Ground continuity check is defeatable for testing two-wire products.
- Easy equipment connections. Plug your equipment right into the NEMA plug on the front panel. No adapters needed!
- J2 and J3 cords allow connection of pigtail power leads.
- Simple test outcome judgement. Green lights mean pass red lights mean fail. Failing tests sound a buzzer as well.
- Ready for your UL Inspector out of the box. NIST Traceable Calibration Certificate to MIL-STD45662-A is included. Cal cert is in accordance with UL guidance.
- Operation Instructions are printed on the rear panel for easy reference.
- In-depth testing. Both true Arc Dectection and Leakage Current circuits test the product to find problems.
- RED lights and a buzzer leave no question if a failure has occurred.
- Expandable for TUV/European Agency Testing. Can be connected to our GF-30ac 25A Ground Bond Tester with optional TEST-LINK™.
- Easy shift-by-shift Function Test. Compatible with our Patented function checker, the HTT-1and HTT-1R (With 0.1 ohm Ground check Pass/Fail Setup).













Reviews
There are no reviews yet.